Oil Furnace Fan Timer Control for PSC Motors
Hydrolevel Company’s OFC-5023 supports 2- and 3-speed PSC motors, integrating adjustable blower timing, accessory connections and diagnostic indicators for oil furnace installations.
hydrolevel.com

Oil furnace fan controls regulate blower operation during heating cycles, helping distribute heat and recover residual energy from the heat exchanger. Replacing older controls can present wiring and compatibility challenges across different furnace configurations. The OFC-5023 addresses these requirements with a universal replacement control designed to simplify installation and servicing.
Universal Replacement for Oil Furnace Controls
The OFC-5023 is compatible with oil furnaces using 2- or 3-speed permanent split capacitor (PSC) motors. It replaces UTEC models 1158-100, 110 and 120, as well as the Resideo ST9103A, with minimal wiring changes. Standard terminals and integrated relays maintain familiar wiring arrangements for HVAC technicians.
Integrated Blower and Accessory Control
The control provides 24 V connections for thermostats and transformers, supporting heating, cooling and dehumidification functions. Its line-voltage outputs include COOL, HEAT, LOW and continuous-fan connections. Dedicated 120 VAC outputs support humidifiers and electronic air cleaners without additional relays, while a separate dehumidifier terminal coordinates blower operation with dehumidification demands.
Adjustable Timing and Diagnostics
Field-adjustable blower ON and OFF delays allow technicians to configure fan operation and residual heat recovery. A counterflow selection with adjustable ON delay supports down-flow and counterflow furnace configurations. DIP switches provide motor-speed and timing adjustments without programming tools.
Diagnostic LEDs indicate thermostat calls, burner and blower operation, limit-circuit status and control self-check conditions, helping technicians identify potential wiring and operating issues.
Technical Specifications
The OFC-5023 operates at 120 VAC, 60 Hz and supports PSC blower motors up to 3/4 HP. Its transformer input is 24 VAC, 40 VA typical, while the humidifier and electronic air cleaner outputs are rated at 120 VAC, 1 A each. Blower ON delays are adjustable from 30 to 240 seconds, and OFF delays from 2 to 8 minutes. Counterflow ON delay settings range from 15 to 48 seconds.
Additional Context:This section details technical specifications and competitive benchmarking not included in the original product announcement.
Blower timing influences heat distribution in forced-air heating systems. The ON delay allows the heat exchanger to warm before air circulation begins, while the OFF delay keeps the blower operating after burner shutdown to recover residual heat.
Compared with the UTEC 1158-120, which provides ON delays of 30–120 seconds and OFF delays of 2–6 minutes, the OFC-5023 offers extended selectable timing ranges. These adjustments provide additional configuration flexibility, subject to the furnace manufacturer's operating requirements.
Hydrolevel Company, headquartered in North Haven, Connecticut, USA, manufactures temperature and liquid-level controls for residential and commercial heating systems, including boiler controls, low-water cut-offs and tank-level controls.
Edited by Sucithra Mani, Induportals editor – adapted by AI.