www.magazine-industry-usa.com
18
'26
Written on Modified on
Allient to showcase industrial I/O and power quality solutions at Automation Fair 2026
Allient Bellevue and Allient Milwaukee present PointMax I/O modules, harmonic filters and PQconnect intelligent control at Booth #951 in Boston.
allient.com

Allient Inc., a global designer and manufacturer of advanced motion, controls and power solutions, is presenting its industrial automation and power quality solutions at Automation Fair 2026, taking place from 16 to 19 November at the Thomas M. Menino Convention & Exhibition Center in Boston, Massachusetts. At Booth #951, visitors can explore technologies from Allient Bellevue (Spectrum Controls) and Allient Milwaukee (TCI), or arrange a meeting with the team during the event.
PointMax I/O and energy monitoring
Allient Bellevue is featuring its PointMax I/O modules, highlighting the 5034-EM-SC Energy Monitoring Module, and visitors can get a first look at the 5034-BACMSTP-SC BACnet Communications Module. The display also includes the currently available 5034-IV8-SC 8-Channel Digital Input Module and 5034-OV8-SC 8-Channel Digital Output Module from the wider PointMax I/O range. Allient Bellevue is also delivering presentation #PS48, “Today’s Technology, Tomorrow’s Results: Leveraging 5034 PointMax I/O to Create What’s Next”, in Room 256 on 17 November (2:00–3:00 p.m.) and 19 November (11:00 a.m.–12:00 p.m.). Curt Simms, Vice President and General Manager of Allient Bellevue, says the team looks forward to connecting with attendees and highlighting the capabilities of the PointMax I/O modules.
Power quality solutions and PQconnect
Allient Milwaukee is showcasing its power quality solutions, including the HGA HarmonicGuard Active Filter, HGP HarmonicGuard Passive Filter, KMG Sine Wave Filter, V1K dV/dt Filter and KDR Line and Load Reactors. Visitors can also learn more about PQconnect intelligent control and its custom Add-On Profile for integration into the Rockwell Automation Studio 5000 platform. The team is introducing a new interactive demonstration this year, with a large touchscreen tablet kiosk that guides visitors through the product lines, 3D drawings and simulations of the filters in action. According to Ashish Bendre, Vice President and Group President (Bellevue, Milwaukee, Oshkosh), Automation Fair is a good venue to show how TCI-branded power quality solutions can help customers solve grid compliance issues, and the intelligent control and monitoring features of PQconnect are major differentiators for customers in the Rockwell ecosystem.
Additional Context:
This section explains general principles of harmonics and motor-side filtering in drive systems not included in the original press release.
Variable frequency drives draw current from the supply in a non-sinusoidal way, which introduces harmonic currents into the electrical network. Harmonics can cause additional heating in transformers and cables and can make it harder for a facility to meet the limits set by utilities or standards. Passive harmonic filters use tuned combinations of inductors and capacitors, while active filters measure the harmonic content and inject compensating current to reduce it.
On the output side, drives supply the motor with fast-switching voltage pulses. Steep voltage rise times, especially with long motor cables, can produce voltage peaks at the motor terminals that stress the winding insulation. dV/dt filters limit the rate of voltage rise, while sine wave filters smooth the output to an almost sinusoidal waveform, and line and load reactors add inductance to reduce current peaks and harmonics.
Edited by an industrial journalist, Lekshman Ramdas, with AI assistance.